General 1 month ago

IAdea Premium Window Mounts

Model                                                   Best ForPWM-011Smaller setups (10-inch room panels)PWM-041Larger setups (15-inch room panels)If it’s an IAdea panel, these mounts will take care of it.Quick Start GuidesGrab the PWM-011 Manual or the PWM-041 Manual to see how easy setup is.
2 hits
Lee Russell (@lee) June 19, 2026
Firmware Release 2 months ago

Jupiter Pana – Update BIOS To Support TPM (Windows 11)

Jupiter have issued a BIOS update to support the Trusted Platform Module 2.0 to be enabled on the OPS module.TPM2.0 is a prerequisite for Windows 11.Update Process1) On the OPS PC, ensure you are logged in with administrator rights2) Download the OPS11 BIOS update from the Software Downloads page of the Jupiter support site (Jupiter.com/support)3) Run the update which will install and restart WindowsChange BIOS Settings1) Ensure a keyboard is attached to the OPS module2) Reboot OPS3) Press ‘ESC’ on keyboard on restart to enter BIOS4) When in the BIOS menu, go to ‘Security’, ‘TPM Operation’ and Enable5) You will also need to enable ‘Secure Boot’6) Hit ‘F10’ to save settingsConfirm TPM Enablement1) Exit BIOS and boot OPS back into Windows2) In the ‘Run’ dialogue box, type ‘tpm.msc’ to confirm that TPM is enabledOnce these steps are complete, you will be able to upgrade to Windows 11.If in doubt, ask AscentaeWe are here to help. If you have any questions or concerns about a solution, please contact the Support Team at support@ascentae.com.
2 hits
Lee Russell (@lee) May 15, 2026
Installation 3 months ago

MAXHUB MTR Functionality Table

Not sure which kit fits your space? We've put together a hardware comparison table below.Here’s the tech specs at a glance for the MAXHUB MTR family. U50 + XC-Kit Pro Bundle V50 V70 W70 XBoard MTR Platform Win11 IOT MDEP (Android 13) MDEP (Android 13) Win11 IOT Win11 IOT Space Small To Medium Small To Medium Medium To Large Medium To Large Small To Large Cam Specs 2 Lens 2 Lens 4 Lens 4 Lens 3 Lens 100 MP Total 100 MP Total 200 MP Total 200 MP Total 150 MP Total Mic Specs 12-Array 12-Array 16-Array 16-Array 16-Array Wire Ingest USB-C (console) USB-C (Console) USB-C (Console) USB-C (Console) HDMI In (Compute) HDMI (compute) HDMI In (Bar) HDMI In (Bar) HDMI In (Bar) USB-C (Console) Wire Ingest @4K (local Only) HDMI On Compute USB-C (Console) USB-C (Console) HDMI On Bar HDMI On Board HDMI In (Bar) HDMI In (Bar) Wireless Sharing (dongle) Yes Yes Yes Yes Yes Wireless Sharing (MAXHUB Share App) Yes No No BETA Yes Sharing Touchback No No No No Coming In Q2 2026 MiraCast No Yes Yes ETA: Q2 2026 Yes Airplay Yes Yes Yes Yes Yes Audio Fence Yes Yes Yes Yes Yes Video Fence Yes Yes Yes Yes Yes Speaker Tracking Yes Yes Yes Yes Yes Auto Framing Smart Gathering (portraits With Room View) Yes Yes Yes Yes No Intelligent Focus (up To 8 Portraits) Yes Yes Yes Yes Yes Multi-Speakers Tracking No No No No Yes AI Facial Enhancement 26H1 26H1 26H1 26H1 No AI EQ Adaptation No No No No Yes Wire BYOD No Yes (USB-C) Yes (USB-C) Yes (USB-C) Yes Via HDMI + USB-B (require Align Ver. 8.6 Or Above) USB-C Power Delivery No 65w (via PSU) 65w (via PSU) No No Wireless BYOD (Dongle) No Yes Yes Yes Yes (require Team Ver. 5.4 Or Above) Wireless BYOD (MAXHUB Share App) No ETA: Q2 2026 ETA: Q2 2026 ETA: Q2 2026 Yes (require Team Ver. 5.4 Or Above) Supported Expansion Mic Apr, 2026 (OTA) June, 2026 (OTA) June, 2026 (OTA) Apr, 2026 (OTA) BM45 Supported Console Main: TCP30T AP30 AP30 TCP31T TCP33T (require Team Ver 5.4 Or Above) Ext: TCP35T LAN Pairing (between Console And Compute Unit) No Yes (BYOD) Yes (BYOD) No No Max. Distance Between Console And Compute In Cat5e 40m 40m (direct Connection) 40m (direct Connection) 40m MAXHUB Pivot Mgmt. Portal Yes Yes Yes Yes Yes Edge Browser No No No No Yes (Pro License) AI Facilitator Yes (Pro License) No No Yes (Pro License) Yes (Pro License) table { font-family: Arial, Helvetica, sans-serif; border-collapse: collapse; width: 100%; } td, th { border: 1px solid #ddd; padding: 8px; } tr:nth-child(even){background-color: #f2f2f2;} tr:hover {background-color: #ddd;} th { padding-top: 12px; padding-bottom: 12px; text-align: left; background-color: #04AA6D; color: white; }
2 hits
Lee Russell (@lee) April 4, 2026
General 4 months ago

PointGrab Sensors - Network Usage

At a high level, network traffic is relatively lightweight. As a general estimate, you can expect approximately 1KB per minute per Area of Interest (AoI), depending on configuration and use case.A Quick Overview:MetricTypical MessageConservative Estimate (Recommended)Size per Message~250 Bytes~1,000 Bytes (1 KB)Usage per Hour~15 KB60 KBUsage per Day~360 KB1.44 MBUsage per Month~10.8 MB43.2 MBA few further points to help provide context...Data transmission varies depending on the type of data being captured (e.g. simple counts vs. more detailed positional data such as XY coordinates).Traffic is calculated per AoI rather than per sensor, meaning a desk-level deployment (with more granular tracking) will typically generate more data than a meeting room setup.Stitching or higher-resolution use cases (e.g. frequent XY updates) will result in slightly higher traffic volumes.During initial deployment and commissioning, network activity may be temporarily higher due to configuration, validation, and testing processes.Firmware updates occur infrequently (typically 1–2 times per year) and will generate higher traffic during those periods, but these are planned and coordinated in advance.Outside of these scenarios, sensors operate with consistent, low-bandwidth communication.In practice, message sizes can be smaller (circa 250 bytes), but we recommend using the ~1KB per minute per AoI estimate as a conservative baseline for planning purposes.
2 hits
Lee Russell (@lee) March 19, 2026
Updates 5 months ago

GoBright Hygienic Mode Update

GoBright updated their hygienic mode feature.This was first introduced during COVID-19, and, if enabled, it requires a desk to be cleaned after every use. The Connect & Glow would turn purple until a card was swiped or if the desk was updated in the portal.However, it is now possible to highlight the desk as required to be cleaned at the end of every day instead of after every check-in. This is configured in the profile attached to the desk.Head to Settings > Work > Profiles and select the profile linked to the desk(s) you wish to enable this for.You can configure your profile from here, depending on your preferences. Here is an example of setting the desk as required to be cleaned at 5pm every day:Please note: If this feature is enabled, the Connect will not turn off outside of office hours until it has been marked as clean.This feature is also supported for the Interact.
2 hits
Lee Russell (@lee) February 8, 2026
Installation 5 months ago

IAdea GoBright Visitor Management

The XDS-1588 and XDS-1588-A cannot exceed Android 7.1. The WRP-1000-A/H cannot  exceed Android 9. Please ensure camera capability before selecting your panel for visitor management if you will be taking a photo of the visitor or scanning QR codes.Last Updated:2nd of December 2025ModelGoBright App VersionAndroid OSCamera QR SupportAscentae approvedXDS-158812.24 to 14.157.1✔(2MP)✔✔XDS-1588-A12.24 to 14.157.1✔(2MP)✔✔WRP-1000-A/H13.28 to 14.159✔(8MP)✔✔WRP-1000-LN/A9❌❌❌WRP-1000-L V2N/AAndroid 12❌❌❌WRP-1000-A V2N/AAndroid 12✔ (8MP)✔✔WRP-1000-H V2N/AAndroid 12✔ (8MP)✔✔ RecommendationIf you are deploying new hardware, stick to the V2 (Android 12) to ensure security compliance (InfoSec). Android 9 is quite dated by modern enterprise standards.